5.5 A Femoral ‘Stealing’ Effect: Presence of Collateral Retrograde Blood Flow Redistribution in the Femoral Bifurcation During Reactive Hyperemia

Abstract

Background & Purpose

The femoral bifurcation houses complex flow recirculation that may be impacted by downstream peripheral resistance; however, conventional ultrasound is unable to quantify multi-directional flow to study these phenomena. The purpose of this study was to examine the multi-directional behavior of blood in the femoral bifurcation during reactive hyperemia (RH) using vector flow imaging.

Methods

Nine healthy adults (25 ± 4 years; 5 men) underwent high-frame-rate ultrasound imaging of their right femoral bifurcation at rest, and during the first cardiac cycle of RH after 5-min of 200 mmHg calf occlusion. Multi-angle Doppler ultrasound was used to qualitatively describe vector blood flow at 750 fps [1]. The bifurcation region was isolated for blood vector dispersion analysis, an index of flow directionality [2].

Results

Blood flow during RH was characterized by near-constant anterograde blood flow to the superficial femoral artery (SFA), adjacent to low/oscillatory flow immediately proximal to the deep femoral artery (DFA) (Figure 1). We observed collateral blood flow redistribution in 3/9 participants, where blood from the DFA appeared to re-enter the SFA during the retrograde flow period. Bifurcation vector dispersion was reduced from baseline (0.53 ± 0.08 vs 0.67 ± 0.09; p < 0.01), but not eliminated, due to preservation of DFA flow reversal.

Conclusion

We demonstrate the presence of distinct, and potentially interacting, blood flow streams within the femoral bifurcation during RH. These observations were made possible by the emerging vector flow imaging technique to study complex hemodynamics in vivo, and suggest novel mechanisms by which blood is distributed to vascular beds, in extreme flow profiles.

Left: Representative example (31 yr old man) of vector projectile imaging of the femoral bifurcation at end-systole; vectors within the red region of interest were extracted to calculate vector dispersion. Right: Representative example of blood vector dispersion at rest and during hyperemia during a single cardiac cycle; values closer to 0 indicate greater dispersion.

References

  1. Yiu BYS, Yu ACH. Least-squares multi-angle doppler estimators for plane-wave vector flow imaging. IEEE Trans Ultrason Ferroelectr Freq Control 2016;63:1733–44.

    Google Scholar 

  2. Pedersen MM, Pihl MJ, Haugaard P, Hansen KL, Lange T, Lönn L, et al. Novel flow quantification of the carotid bulb and the common carotid artery with vector flow ultrasound. Ultrasound Med Biol 2014;40:2700–6.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jason Au.

Rights and permissions

This is an open access article distributed under the CC BY-NC 4.0 license (http://creativecommons.org/licenses/by-nc/4.0/).

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Au, J., Amelard, R., Yiu, B. et al. 5.5 A Femoral ‘Stealing’ Effect: Presence of Collateral Retrograde Blood Flow Redistribution in the Femoral Bifurcation During Reactive Hyperemia. Artery Res 25 (Suppl 1), S41 (2019). https://doi.org/10.2991/artres.k.191224.034

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2991/artres.k.191224.034