Skip to main content

Measurement of Instantaneous Wave-free Ratio through a Diagnostic Catheter: Comparison of the Results between 4Fr and 5Fr

Abstract

Background

Clinical evidence of coronary pressure assessment through a diagnostic catheter is limited. The aim of this study was to assess the difference, safety, and rate of successful measurement of Instantaneous Wave-free Ratio (iFR) through 4Fr and 5Fr diagnostic catheters.

Methods

This single-centre prospective study included 32 lesions among 24 patients exhibiting intermediate coronary stenosis on coronary angiography. iFR measurements were performed through 4Fr and 5Fr diagnostic catheters for each lesion. The primary outcome was the reliability, as assessed by a Bland—Altman plot, for comparison of the mean differences [mean ± 2 Standard Deviations (SDs)], and the agreement on the Kappa coefficient, using a threshold iFR value of 0.89. The secondary outcome was the rate of successful iFR measurement. Safety was assessed by procedural complications and in-hospital Major Adverse Cardiac Events (MACE).

Results

The mean difference was −0.0003 ± 0.058, according to the Bland–Altman plot. One lesion was out of the range of 2 SDs. There was good agreement (Kappa coefficient = 0.85), and the correlation coefficient between the 4Fr and 5Fr catheters was 0.948 (p < 0.001). The success rate was not significantly different between the 4Fr and 5Fr catheters (90.6% vs. 96.9%, p = 0.09), although the 4Fr catheter had a lower success rate. No procedural complications or in-hospital MACE occurred.

Conclusion

Our findings suggest that iFR measurements could be safely performed, with similar reliability and success rate, through either the 4Fr or 5Fr diagnostic catheter.

Highlights

  • Instantaneous Wave-free Ratio (iFR) measurements through 4Fr and 5Fr diagnostic catheters.

  • Correlation and agreement of iFR between 4Fr and 5Fr.

  • To compare the successful measurement of iFR values.

References

  1. Sen S, Escaned J, Malik IS, Mikhail GW, Foale RA, Mila R, et al. Development and validation of a new adenosine-independent index of stenosis severity from coronary wave-intensity analysis: results of the ADVISE (ADenosine Vasodilator Independent Stenosis Evaluation) study. J Am Coll Cardiol 2012;59:1392–402.

  2. Sen S, Asrress KN, Nijjer S, Petraco R, Malik IS, Foale RA, et al. Diagnostic classification of the instantaneous wave-free ratio is equivalent to fractional flow reserve and is not improved with adenosine administration. Results of CLARIFY (Classification Accuracy of Pressure-Only Ratios Against Indices Using Flow Study). J Am Coll Cardiol 2013;61:1409–20.

    Google Scholar 

  3. Petraco R, Sen S, Nijjer S, Escaned J, Davies JE. Baseline coronary pressures, instant wave-free ratio (iFR) and Pd/Pa: making the most of available information. EuroIntervention 2013;9:170–23.

    Google Scholar 

  4. Johnson NP, Jeremias A, Zimmermann FM, Adjedj J, Witt N, Hennigan B, et al. Continuum of vasodilator stress from rest to contrast medium to adenosine hyperemia for fractional flow reserve assessment. JACC Cardiovasc Interv 2016;9:757–67.

    Google Scholar 

  5. Davies JE, Sen S, Dehbi HM, Al-Lamee R, Petraco R, Nijjer SS, et al. Use of the instantaneous wave-free ratio or fractional flow reserve in PCI. N Engl J Med 2017;376:1824–34.

    Google Scholar 

  6. Götberg M, Christiansen EH, Gudmundsdottir IJ, Sandhall L, Danielewicz M, Jakobsen L, et al. Instantaneous wave-free ratio versus fractional flow reserve to guide PCI. N Engl J Med 2017;376:1813–23.

    Google Scholar 

  7. Pijls NHJ, Kern MJ, Yock PG, De Bruyne B. Practice and potential pitfalls of coronary pressure measurement. Catheter Cardiovasc Interv 2000;49:1–16.

    Google Scholar 

  8. Toth GG, Johnson NP, Jeremias A, Pellicano M, Vranckx P, Fearon WF, et al. Standardization of fractional flow reserve measurements. J Am Coll Cardiol 2016;68:742–53.

    Google Scholar 

  9. Kawase Y, Matsuo H, Akasaka T, Shiono Y, Tanaka N, Amano T, et al. Clinical use of physiological lesion assessment using pressure guidewires: an expert consensus document of the Japanese Association of Cardiovascular Intervention and Therapeutics. Cardiovasc Interv Ther 2019;34:85–96.

    Google Scholar 

  10. Arashi H, Yamaguchi J, Ri T, Tanaka K, Otsuki H, Nakao M, et al. Evaluation of the cut-off value for the instantaneous wave-free ratio of patients with aortic valve stenosis. Cardiovasc Interv Ther 2019;34:269–74.

    Google Scholar 

  11. Nakayama M, Chikamori T, Uchiyama T, Kimura Y, Hijikata N, Ito R, et al. Effects of caffeine on fractional flow reserve values measured using intravenous adenosine triphosphate. Cardiovasc Interv Ther 2018;33:116–24.

    Google Scholar 

  12. Legalery P, Seronde MF, Meneveau N, Schiele F, Bassand JP. Measuring pressure-derived fractional flow reserve through four French diagnostic catheters. Am J Cardiol 2003;91:1075–8.

    Google Scholar 

  13. Uhlemann M, Möbius-Winkler S, Mende M, Eitel I, Fuernau G, Sandri M, et al. The Leipzig prospective vascular ultrasound registry in radial artery catheterization: impact of sheath size on vascular complications. JACC Cardiovasc Interv 2012;5:36–43.

    Google Scholar 

  14. Polimeni A, Passafaro F, De Rosa S, Sorrentino S, Torella D, Spaccarotella C, et al. Clinical and procedural outcomes of 5-French versus 6-French sheaths in transradial coronary interventions. Medicine (Baltimore) 2015;94:e2170.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shinichiro Masuda.

Additional information

Peer review under responsibility of the Association for Research into Arterial Structure and Physiology

Data availability statement: The authors confirm that the data supporting the findings of this study are available within the article and its supplementary materials.

Rights and permissions

This is an open access article distributed under the CC BY-NC 4.0 license (http://creativecommons.org/licenses/by-nc/4.0/).

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Masuda, S., Uemura, R., Saiki, Y. et al. Measurement of Instantaneous Wave-free Ratio through a Diagnostic Catheter: Comparison of the Results between 4Fr and 5Fr. Artery Res 26, 143–147 (2020). https://doi.org/10.2991/artres.k.200620.001

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2991/artres.k.200620.001

Keywords