P53 Zero Flow Pressure (Pinfinity) is Larger than Mean Circulatory Filling Pressure. A Systematic Review and Meta-Analysis

Abstract

Background

Zero flow pressure (P∞), the steady-state pressure following cardiac arrest or cessation of flow is often assumed to equal mean circulatory filling pressure (MCFP). [1] However, this assumes complete equilibration of circulatory pressures, which may not occur if there is a ‘critical closing pressure’ or ‘Waterfall’ in the circulation. We undertook a systematic review and meta-analysis to obtain robust estimates of P∞ and compared this with MCFP measured in the same studies.

Methods

A literature search was performed using PubMed and was limited to full articles in English using the search terms “mean circulatory filling pressure” OR “critical closing” OR “zero-flow”. Only data relating to measurements of pressure following cardiac arrest or cessation of blood flow were included. Other exclusions were: individual case-reports, pregnancy, non-adult animals, not mammalian, or any non-human models of disease. Meta-analysis was performed using a random effects model in Stata 15.1. Data are mean (95% confidence intervals).

Results

A total of 1082 unique publications were identified; 1062 were excluded during screening. The remaining 20 studies with P∞ data were used to perform a meta-analysis. These included data from dog, rat, pig and human; 8 of these articles also provided data on MCFP. From this analysis P∞ = 26.5(23.4, 29.5) mmHg (n = 20) and the difference between P∞ and MCFP was 15.1(12.0, 18.3) mmHg (n = 8).

Conclusions

P∞ and MCFP differ substantially, indicating non-equilibration of pressures in the circulation following cessation of flow at least in the short-term (seconds to minutes).

References

  1. Guyton AC, Polizo D, Armstrong GG. Mean circulatory filling pressure measured immediately after cessation of heart pumping. Am J Physiol 1954;179:261–7.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hughes, A., Parker, K. & Khir, A. P53 Zero Flow Pressure (Pinfinity) is Larger than Mean Circulatory Filling Pressure. A Systematic Review and Meta-Analysis. Artery Res 24, 94 (2018). https://doi.org/10.1016/j.artres.2018.10.106

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1016/j.artres.2018.10.106